Sign In | Join Free | My adobecards.com
China DONGGUAN YUYANG INSTRUMENT CO., LTD logo
DONGGUAN YUYANG INSTRUMENT CO., LTD
Verified Supplier

8 Years

Home > Wire Testing Equipment >

IEC 60332-3 Vertical Flammability Tester For Burning Behaviour Of Bunched Cables

DONGGUAN YUYANG INSTRUMENT CO., LTD
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

IEC 60332-3 Vertical Flammability Tester For Burning Behaviour Of Bunched Cables

  • 1
  • 2

Brand Name : YUYANG

Model Number : BVC

Certification : ISO

Place of Origin : CHINA

MOQ : 1 Set

Price : Negotiable

Supply Ability : 5 sets

Delivery Time : 30 days

Packaging Details : Plywood case

Test standard : IEC 60332-3-10,IEC 60332-3-21~25

Application field : Wire&cable

Size : 1120 mm (W) x 2200 mm (D) x 5070 mm (H)

Color : White

Electrical : 110V AC 60Hz / 230V AC 50Hz, 5A

Ambient Temperature : Operating 10°C to 35°C

Warranty : 1 Year

Weight : 500KG

Keyword : Bunched Cable Vertical Flame Tester

Contact Now

IEC 60332-3 Vertical Flammability Tester For Burning Behaviour Of Bunched Cables

Introduction

Bunched Cable Vertical Flame Spread Tester is a series conforming to IEC 60332-3-10 (Category A~D) standards. The test measures the expansion of vertical flame to the electronically or optically vertical cable or wire using the standard ignition source while supplying a certain amount of air to a chamber of a defined volume.
Additionally, if bunched cable vertical flame spread testers burner is adjusted by 20 degrees angle, it can be measure under IEEE 383(IEEE 1202) standard. Also, if Heat Release Facility is attached, it can measure fire dynamics value as H.R.R (Heat Release Rate), S.P.R (Smoke Production Rate) and so on.

Standards:

  • IEC 60332-3-10:2000

  • IEC 60332-3-21~25:2000

Features

  • ​Test chamber has the dimension of 1,000±100(W) x 2,000±100(D) x 4,000±100(H) mm.

  • The bottom surface of the test chamber is higher than the ground while the rear side is supplemented with insulated material to insulate it from heat.At the lower section of the test chamber, there is a 800±20(W)x 400±10(D) sized hole at the 150±10mm position from the front side of the chamber to supply the air.

  • ​There is a 300±30(W)x1,000±100(D) sized exhaust hole at the rear corner of the top section of the test chamber to allow emission of the smoke during the test.

  • ​A flame trap is installed at the front side of the burner of the vertical flame spread tester to prevent backfire by propane to ensure the utmost safety.

  • ​Unlike the conventional IEC60332-3 equipment, the vertical flame spread tester records all control and test conditions with the computer to add user friendliness.

  • ​If stop the excessive combustion test due to Water Spray device installed for extinguish.

  • ​The program on the requirement on standard and 70,000Btu/h can be program.

  • ​Wide stainless steel ladder dimensions: 500(W) ×3, 500(H) mm.

  • ​Standard stainless steel ladder dimensions: 800(W) ×3, 500(H).

  • Two sets of standard propane burner and venturi mixtures.

  • ​Follow the standard category can program for select a test.

Installation requirements of Vertical Flame Tester for Burning Behaviour of Bunched Cables

Electrical 110V AC 60Hz / 230V AC 50Hz, 5A
​Ambient Temperature Operating 10°C to 35°C
Size 1120 mm (W) x 2200 mm (D) x 5070 mm (H)
Weight 500KG
Gas air and propane

IEC 60332-3 Vertical Flammability Tester For Burning Behaviour Of Bunched Cables


Product Tags:

spark testing equipment

      

flame test chamber

      
 IEC 60332-3 Vertical Flammability Tester For Burning Behaviour Of Bunched Cables Manufactures

IEC 60332-3 Vertical Flammability Tester For Burning Behaviour Of Bunched Cables Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: DONGGUAN YUYANG INSTRUMENT CO., LTD
*Subject:
*Message:
Characters Remaining: (0/3000)